TY - JOUR
T1 - Detection of Unlabeled Polystyrene Micro- and Nanoplastics in Mammalian Tissue by Optical Photothermal Infrared Spectroscopy
AU - Duswald, Kristina
AU - Pichler, Verena
AU - Kopatz, Verena
AU - Limberger, Tanja
AU - Karl, Verena
AU - Hennerbichler, David
AU - Zimmerleiter, Robert
AU - Wadsak, Wolfgang
AU - Hettich, Mike
AU - Gruber, Elisabeth S.
AU - Kenner, Lukas
AU - Brandstetter, Markus
N1 - Publisher Copyright:
© 2025 The Authors. Published by American Chemical Society
PY - 2025/8/12
Y1 - 2025/8/12
N2 - In this study, we investigate the efficacy of optical photothermal infrared (O-PTIR) spectroscopy, also known as mid-infrared photothermal (MIP) microscopy, for label-free and nondestructive detection of micro- and nanoplastics (MNPs) down to diameters of 200 nm in mammalian tissues. Experiments with both in vitro three-dimensional cell cultures derived from HTC116 colorectal cancer cell line and in vivo mouse tissue models were conducted. Spherical polystyrene particles served as reliable model systems for evaluating spatial resolution limits and quality of spectra. Our findings demonstrate the superior resolution of O-PTIR in imaging individual particles of 200 nm in mouse kidney tissues, surpassing the capabilities of traditional Fourier transform infrared (FTIR) spectroscopy. Furthermore, we apply a semiautomated image analysis that incorporates machine learning algorithms to accelerate the detection process, thus improving throughput and minimizing the potential for human error. The results confirm that O-PTIR is able to provide high-quality, artifact-free spectral images in a contact-less manner and significantly outperforms traditional infrared spectroscopy in terms of spatial resolution and signal-to-noise ratio in complex biological matrices.
AB - In this study, we investigate the efficacy of optical photothermal infrared (O-PTIR) spectroscopy, also known as mid-infrared photothermal (MIP) microscopy, for label-free and nondestructive detection of micro- and nanoplastics (MNPs) down to diameters of 200 nm in mammalian tissues. Experiments with both in vitro three-dimensional cell cultures derived from HTC116 colorectal cancer cell line and in vivo mouse tissue models were conducted. Spherical polystyrene particles served as reliable model systems for evaluating spatial resolution limits and quality of spectra. Our findings demonstrate the superior resolution of O-PTIR in imaging individual particles of 200 nm in mouse kidney tissues, surpassing the capabilities of traditional Fourier transform infrared (FTIR) spectroscopy. Furthermore, we apply a semiautomated image analysis that incorporates machine learning algorithms to accelerate the detection process, thus improving throughput and minimizing the potential for human error. The results confirm that O-PTIR is able to provide high-quality, artifact-free spectral images in a contact-less manner and significantly outperforms traditional infrared spectroscopy in terms of spatial resolution and signal-to-noise ratio in complex biological matrices.
UR - https://www.scopus.com/pages/publications/105013667301
U2 - 10.1021/acs.analchem.4c05400
DO - 10.1021/acs.analchem.4c05400
M3 - Article
AN - SCOPUS:105013667301
SN - 0003-2700
VL - 97
SP - 16714
EP - 16722
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 31
ER -