TY - JOUR
T1 - Advancing elemental analysis by collision/reaction cell technology and micro-droplet calibration for bioimaging applications by LA-ICP-TOFMS
AU - Theiner, Sarah
AU - Foels, Elisabeth
AU - Koellensperger, Gunda
N1 - Publisher Copyright:
© 2024 The Authors
Accession Number
WOS:001343627200001
PY - 2024/12/15
Y1 - 2024/12/15
N2 - Background: Bioimaging applications by laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOFMS) require comprehensive elemental analysis spanning the entire mass range. Within biological systems, endogenous elements are critical for maintaining metal homeostasis in cells, a fundamental aspect in disease progression when disrupted. Additionally, elements from the higher mass range may originate from various sources such as metal-tags for immuno-mass spectrometry, nanoparticles, or metal-based anticancer drugs. This study assesses the efficacy of collision/reacton cell (CCT) mode for simultaneously analysing elements across the complete mass spectrum. Furthermore, we demonstrate the accuracy of the LA-ICP-TOFMS methodology through the analysis of serum reference material. Results: Our findings demonstrate that the CCT mode outperforms the standard/no gas mode for LA-ICP-TOFMS measurements, particularly in quantifying endogenous elements susceptible to interferences. Through the analysis of picolitre-volume micro-droplet standards and serum reference material (deposited as micro-droplets), we observed accurate quantification of elements such as iron and selenium, with isotope ratios closely resembling natural compositions. As key advantage, the utilization of the CCT mode eliminated the need for labor-intensive post-data processing, streamlining analytical procedures. Additionally, the CCT mode also provided enhanced sensitivity (factor of 1.5–2) for elements in the higher mass range compared to the standard mode, without compromising the sensitivity for endogenous elements. Significance: We successfully integrated Seronorm serum reference material-containing micro-droplets into LA-ICPMS bioimaging workflows for quality control, enabling validated measurements of key biological elements. The use of the CCT mode is highly recommended for bioimaging applications that address the analysis of elements across the entire mass range.
AB - Background: Bioimaging applications by laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOFMS) require comprehensive elemental analysis spanning the entire mass range. Within biological systems, endogenous elements are critical for maintaining metal homeostasis in cells, a fundamental aspect in disease progression when disrupted. Additionally, elements from the higher mass range may originate from various sources such as metal-tags for immuno-mass spectrometry, nanoparticles, or metal-based anticancer drugs. This study assesses the efficacy of collision/reacton cell (CCT) mode for simultaneously analysing elements across the complete mass spectrum. Furthermore, we demonstrate the accuracy of the LA-ICP-TOFMS methodology through the analysis of serum reference material. Results: Our findings demonstrate that the CCT mode outperforms the standard/no gas mode for LA-ICP-TOFMS measurements, particularly in quantifying endogenous elements susceptible to interferences. Through the analysis of picolitre-volume micro-droplet standards and serum reference material (deposited as micro-droplets), we observed accurate quantification of elements such as iron and selenium, with isotope ratios closely resembling natural compositions. As key advantage, the utilization of the CCT mode eliminated the need for labor-intensive post-data processing, streamlining analytical procedures. Additionally, the CCT mode also provided enhanced sensitivity (factor of 1.5–2) for elements in the higher mass range compared to the standard mode, without compromising the sensitivity for endogenous elements. Significance: We successfully integrated Seronorm serum reference material-containing micro-droplets into LA-ICPMS bioimaging workflows for quality control, enabling validated measurements of key biological elements. The use of the CCT mode is highly recommended for bioimaging applications that address the analysis of elements across the entire mass range.
KW - Bioimaging
KW - Collision/reaction cell
KW - LA-ICP-TOFMS
KW - Micro-droplet calibration
UR - http://www.scopus.com/inward/record.url?scp=85206946443&partnerID=8YFLogxK
U2 - 10.1016/j.aca.2024.343345
DO - 10.1016/j.aca.2024.343345
M3 - Article
AN - SCOPUS:85206946443
SN - 0003-2670
VL - 1332
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
M1 - 343345
ER -