Hit-Time and Hit-Position Reconstruction in Strips of Plastic Scintillators Using Multithreshold Readouts

  • N. G. Sharma (Corresponding author)
  • , M. Silarski
  • , J. Chhokar
  • , E. Czerwinski
  • , C. Curceanu
  • , K. Dulski
  • , K. Farbaniec
  • , A. Gajos
  • , R. Del Grande
  • , M. Gorgol
  • , B. C. Hiesmayr
  • , B. Jasinska
  • , K. Kacprzak
  • , L. Kaplon
  • , D. Kisielewska
  • , K. Klimaszewski
  • , G. Korcyl
  • , P. Kowalski
  • , N. Krawczyk
  • , W. Krzemien
  • T. Kozik, E. Kubicz, M. Mohammed, Sz Niedzwiecki, M. Palka, M. Pawlik-Niedzwiecka, L. Raczynski, J. Raj, S. Sharma, S. Shivani, R. Y. Shopa, M. Skurzok, W. Wislicki, B. Zgardzinska, P. Moskal

Publications: Contribution to journal › Article › Peer Reviewed

Abstract

In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This article is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in multivoltage-technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well-defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5× 9× 300 mm3. The obtained time-of-flight (TOF) and spatial resolutions amount to 325 ps (FWHM) and 25 mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using the linear fitting method. The best TOF resolution was obtained with this method at four predefined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two predefined threshold levels. Although the algorithm of the linear fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.

Original languageEnglish
Pages (from-to)528-537
Number of pages10
JournalIEEE Transactions on Radiation and Plasma Medical Sciences
Volume4
Issue number5
DOIs
Publication statusPublished - Sept 2020

Funding

This work was supported in part by the Polish National Center for Research and Development under Grant INNOTECH-K1/IN1/64/159174/NCBR/12, in part by the Foundation for Polish Science through the MPD and TEAM under Grant POIR.04.04.00-00-4204/17 programmes, in part by the National Science Centre of Poland under Grant 2016/21/B/ST2/01222 and Grant 2017/25/N/NZ1/00861, in part by the Ministry for Science and Higher Education under Grant 6673/IA/SP/2016, Grant 7150/E-338/SPUB/2017/1, and Grant 7150/E-338/M/2017, and in part by the Austrian Science Fund under Grant FWF-P26783 and DSC grants.

Austrian Fields of Science 2012

  • 206003 Medical physics
  • 302054 Nuclear medicine

Keywords

  • J-PET detector
  • Mahalanobis distance
  • medical imaging
  • spatial resolution
  • TOF resolution
  • J-PET
  • SIGNALS
  • SENSITIVITY
  • RESOLUTION
  • DETECTORS
  • DIGITIZER
  • LIBRARY

Fingerprint

Dive into the research topics of 'Hit-Time and Hit-Position Reconstruction in Strips of Plastic Scintillators Using Multithreshold Readouts'. Together they form a unique fingerprint.

Cite this